2016 New Sales m66/m69 MS200

FOB Reference Price:Get Latest Price
US $0-1 / Piece | 1 Piece/Pieces pcs (Min. Order)
Supply Ability:
10000 Piece/Pieces per Month MONTH
Port:
SHENZHEN
Overview
Quick Details
Type:
Biochemical Analysis System
Model Number:
MS200
Place of Origin:
Guangdong, China (Mainland)
Color::
Green
Certifications::
CE RoHS
Usage::
Process Testing Machine
Power::
Electronic
Display::
4.3 inch LCD
Heart Rate Accuracy::
±1BPM
Stock Status:
In Stock
Delivery Time:
Fast 2 days after payment confirm
Operator interface:
English
Products:
NIBP patient simulator
Packaging & Delivery
Packaging Details
Carboard, 27 cm x 26.5 cm x 13.2 cm, 3.5kg
Delivery Time
2-7 days

2016 New Sales m66/m69

Model No.: MS200

 

m66/m69 Product overview:
MS200 NIBP Simulator is a multi-purpose tester applied to the oscillometric Non-Invasive Blood Pressure (NIBP)Monitor.

It can test the performance of multiform blood pressure monitor,

provides dynamic blood pressure simulations,

static pressure calibration,

automated leak testing,

and pressure relief valve testing.


m66/m69 Main features
1. 4.3" LCD display,interface is concision,operation is simple and convenient.
2. Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
3. Build-in pump provides pressure source with leak and pressure relief tests  
4. NIBP simulations for both arm and wrist cuffs.
5. Provides adult,neonate, seven variations patients conditions,user-defined simulations.
6. Provides arrhythmias,respiratory artifact simulations.
7. Built-in air chamber to simulate adult and neonate cuff.

m66/m69 Main Parameters
1. Heart Rate for NIBP Simulations
Heart Rate Accuracy:   ±1BPM
Patient Conditions:
Weak pulse,Tachycardia,Obese ,Geriatric: ±1% ±1BPM
Mild exercise:     ±1.5% ±1BPM
Strenuous exercise:    ±3% ±1BPM
2.Pressure measurement
Units:      mmHg,kPa,cmH2O,inH2O,psi
Range:      0 mmHg-400 mmHg
Resolution: 1 mmHg,  0.1 kPa, 1 cmH2O,  1 inH2O,  0.1 psi 
Accuracy:   0 - 300 mmHg: ±0.5 % of reading ±1 mmHg           301 - 400 mmHg: ±2 % of reading 
3. Pressure Generation
Pressure Generator, Static Pressure Range: 50 mmHg-400 mmHg
Difference between target pressure and actual pressure : ±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
Internal leak rate: <2 mmHg per minute, with a minimum volume of 300 cc
4. Power
100 - 240 V  AC 50/60 Hz, 60 VA
5.Environmental Conditions
Working temperature:  15°C to 40°C(59°F to 104°F)
Storage temperature:  -20°C to +65°C(-4°F to +149°F)
Relative humidity:    < 90%
6.Display
65k colors 4.3 inch TFT Display, brightness can be changed.
7. Size (L x W x H)
27 cm x 26.5 cm x 13.2 cm
8. Weight
3.5kg

....